Student Feedback on Course Changes
- 64Unfamiliar
- 0Learning
- 0Familiar
- 0Mastered
64 questions
- 1When a heat exchanger problem asks how much heat-transfer surface is required, the objective is_____.
Hint
This objective concerns determining the device’s required size.
Answer
sizing
- 2The log mean temperature difference method is especially convenient for parallel-flow and_____heat exchangers.
Hint
This is the other simple flow arrangement in which the fluids move in opposite directions.
Answer
counter-flow
- 3To apply the log mean temperature difference method directly, the inlet and outlet temperatures of both fluids must be_____.
Hint
The method uses temperature differences at both ends of the exchanger.
Answer
known
- 4For a complicated heat-exchanger geometry or when outlet temperatures are unknown, a useful alternative is the_____.
Hint
This method uses heat-transfer effectiveness and the number of transfer units.
Answer
effectiveness NTU method
- 5The heat-capacity rate of a flowing fluid is calculated as mass flow rate multiplied by specific heat, or_____.
Hint
It combines how much fluid flows with how much energy is needed to change its temperature.
Answer
m˙cp
- 6With no phase change, the heat-transfer rate for a fluid stream is the product of mass flow rate, specific heat, and temperature change:_____.
Hint
Use the fluid heat-capacity rate multiplied by its temperature change.
Answer
Q=m˙cpΔT
- 7For an insulated heat exchanger at steady state, the heat lost by the hot fluid equals the heat_____by the cold fluid.
Hint
The cold stream gains the energy that the hot stream loses.
Answer
accepted
- 8The ratio of the smaller fluid heat-capacity rate to the larger one is called the capacity-rate_____.
Hint
It compares the minimum and maximum heat-capacity rates.
Answer
ratio
- 9In the effectiveness NTU method, heat-transfer effectiveness is the actual heat transfer divided by the_____heat transfer.
Hint
This is the greatest possible heat transfer for the inlet conditions and heat-capacity rates.
Answer
maximum
- 10In the effectiveness NTU method, the maximum possible heat transfer uses the minimum heat-capacity rate and the largest possible inlet temperature difference:_____.
Hint
Pair the smaller heat-capacity rate with the hot-inlet to cold-inlet temperature difference.
Answer
Qmax=Cmin(Th,in−Tc,in)
- 11The number of transfer units is defined using the effective heat-transfer coefficient, area, and minimum heat-capacity rate:_____.
Hint
It increases with heat-transfer area and decreases with the smaller heat-capacity rate.
Answer
NTU=UA/Cmin
- 12A standard heat-exchanger analysis assumes the system is at_____.
Hint
Under this assumption, conditions do not change with time.
Answer
steady state
- 13In the standard heat-exchanger model, fluid and material properties are assumed to remain_____.
Hint
The model neglects changes in properties as temperature changes.
Answer
constant
- 14Assuming no heat losses to the surroundings means the heat exchanger is treated as_____.
Hint
This condition prevents heat from crossing the exchanger’s outer boundary.
Answer
adiabatic
- 15Neglecting heat conduction along the length of the tube means assuming there is no_____conduction.
Hint
This describes conduction in the direction along the tube.
Answer
axial
- 16A thin tube wall is assumed to have negligible_____resistance.
Hint
This is resistance to heat transfer through the tube material.
Answer
conduction
- 17Deposits or buildup on the inside or outside of a tube are called_____and add thermal resistance.
Hint
This term describes unwanted material accumulating on heat-transfer surfaces.
Answer
fouling
- 18In the shell-and-tube example, heat transfer where a tube bends around at the end is assumed to be_____compared with heat transfer along a pass.
Hint
The model focuses on the straight pass length rather than the turns.
Answer
negligible
- 19For the shell-and-tube internal-convection calculation, the tube flow is assumed to be_____.
Hint
The velocity and thermal flow patterns are treated as established along the tube.
Answer
fully developed
- 20When the tube wall and fouling resistances are neglected, the effective heat-transfer coefficient accounts for convection on the_____and cold sides.
Hint
It combines the two fluid-side convection resistances.
Answer
hot
- 21For parallel flow, the first end temperature difference pairs the hot-fluid inlet with the cold-fluid_____.
Hint
In parallel flow, both fluids enter at the same end.
Answer
inlet
- 22For parallel flow, the second end temperature difference pairs the hot-fluid outlet with the cold-fluid_____.
Hint
Both streams leave at the same end in parallel flow.
Answer
outlet
- 23For counter flow, the hot-fluid inlet is alongside the cold-fluid_____.
Hint
The streams travel in opposite directions, so the hot inlet is at the cold stream’s leaving end.
Answer
outlet
- 24For counter flow, the hot-fluid outlet is alongside the cold-fluid_____.
Hint
The streams travel in opposite directions, placing the hot outlet at the cold stream’s entering end.
Answer
inlet
- 25The log mean temperature difference is calculated from the two end temperature differences using their difference divided by the natural logarithm of their_____.
Hint
The denominator involves the natural logarithm of one end difference divided by the other.
Answer
ratio
- 26For the cooling example, the parallel-flow log mean temperature difference was_____degrees Celsius.
Hint
It was calculated using end differences of 65 and 15 degrees Celsius.
Answer
34.1
- 27For the same cooling example, the counter-flow log mean temperature difference was_____degrees Celsius.
Hint
The counter-flow end differences were 45 and 35 degrees Celsius.
Answer
39.8
- 28A more nearly constant temperature difference along a counter-flow exchanger helps it achieve a larger log mean temperature difference and require_____area for the same heat transfer.
Hint
A larger mean driving temperature difference allows a smaller surface to transfer the same heat.
Answer
less
- 29In the cooling example, the heat lost by the hot stream was_____kilowatts.
Hint
The hot-side energy balance gave a value just over two hundred kilowatts.
Answer
210
- 30In the cooling example, the calculated cold-fluid outlet temperature was_____degrees Celsius.
Hint
The estimate used the cold-side energy balance and a tabulated liquid specific heat.
Answer
35
- 31The parallel-flow area required in the cooling example was_____square meters.
Hint
The result was a little more than three square meters.
Answer
3.13
- 32The counter-flow area required in the cooling example was_____square meters.
Hint
This area was smaller than the parallel-flow result.
Answer
2.68
- 33Changing the cooling example from parallel flow to counter flow reduced the required area by approximately_____percent.
Hint
Compare the two calculated areas, 3.13 and 2.68 square meters.
Answer
14
- 34In a shell-and-tube heat exchanger, a tube pass is one trip down the shell; returning to the starting end therefore takes_____passes.
Hint
A return trip consists of one pass in each direction.
Answer
two
- 35Baffles create multiple shell passes by forcing shell-side fluid to move_____across the tubes.
Hint
The fluid must repeatedly change direction as it crosses the tube bundle.
Answer
back and forth
- 36For a shell-and-tube exchanger with one shell pass and an even number of tube passes, the example selected the corresponding_____correlation.
Hint
The correlation is chosen to match the exchanger’s geometry and pass arrangement.
Answer
shell-and-tube
- 37In the shell-and-tube sizing example, the heat transfer on the known cold side was used with an energy balance to determine the hot-oil_____.
Hint
The hot-side flow quantity was unknown, but the heat transferred was known from the cold side.
Answer
mass flow rate
- 38In the shell-and-tube example, the cold-side heat-capacity rate was approximately_____watts per kelvin.
Hint
It was slightly greater than ten thousand watts per kelvin.
Answer
10,000
- 39In the shell-and-tube example, the calculated hot-oil mass flow rate was_____kilograms per second.
Hint
The energy balance produced a value a little above five kilograms per second.
Answer
5.2
- 40In the shell-and-tube example, the hot-side heat-capacity rate was about 12,152 watts per kelvin, making it the_____heat-capacity rate.
Hint
It was larger than the cold-side value of about 10,000 watts per kelvin.
Answer
maximum
- 41For the shell-and-tube example, the capacity-rate ratio was approximately_____.
Hint
It is the smaller heat-capacity rate divided by the larger one.
Answer
0.86
- 42The shell-and-tube example had a heat-transfer effectiveness of_____.
Hint
Effectiveness was found by comparing actual heat transfer with maximum possible heat transfer.
Answer
0.483
- 43The shell-and-tube example required an NTU value of approximately_____.
Hint
This value was obtained from the shell-and-tube correlation using the effectiveness and capacity-rate ratio.
Answer
1
- 44The shell-and-tube example required almost_____square meters of total tube heat-transfer area.
Hint
The area was calculated from NTU, the effective coefficient, and the minimum heat-capacity rate.
Answer
30
- 45For ten tubes with eight passes each, the total straight tube area is the number of tubes multiplied by the perimeter of one tube and the pass length times the number of_____.
Hint
Each tube contributes its circumference multiplied by the length of each repeated straight section.
Answer
passes
- 46For a cylindrical tube of diameter D, the perimeter used to calculate its lateral heat-transfer area is_____.
Hint
This is the circumference of a circle.
Answer
πD
- 47The calculated length of each tube pass in the shell-and-tube example was approximately_____meters.
Hint
The total area was divided across ten tubes and eight passes per tube.
Answer
4.7
- 48For turbulent internal flow in a tube, the example treated the flow as fully developed after approximately_____tube diameters.
Hint
The required entrance length was expressed as a multiple of the tube diameter.
Answer
10
- 49The dimensionless group used to characterize the tube flow regime from mass flow rate, diameter, and viscosity is the_____number.
Hint
This number indicates whether flow is laminar or turbulent.
Answer
Reynolds
- 50The dimensionless group that appears with Reynolds number in the turbulent-flow Nusselt correlation is the_____number.
Hint
It relates momentum diffusivity to thermal diffusivity.
Answer
Prandtl
- 51The dimensionless number connecting the convection coefficient, tube diameter, and fluid thermal conductivity is the_____number.
Hint
Its definition includes the heat-transfer coefficient multiplied by a characteristic length.
Answer
Nusselt
- 52In the shell-and-tube example, the internal-convection calculation gave a Nusselt number of approximately_____.
Hint
This value was obtained from the turbulent-flow correlation.
Answer
120
- 53The cold-side convection coefficient in the shell-and-tube example was found by combining the Nusselt number with the fluid’s_____.
Hint
This fluid property appears in the definition Nu=hD/k.
Answer
thermal conductivity
- 54In the truck-coolant example, both fluids were described as_____because each flowed in separate tubes or channels and could not mix across them.
Hint
The term describes streams that remain separated into distinct flow passages.
Answer
unmixed
- 55When both fluids are unmixed in a single-pass cross-flow exchanger, the effectiveness relation is selected as a function of NTU and the capacity-rate_____.
Hint
The relation depends on NTU and the comparison between the minimum and maximum heat-capacity rates.
Answer
ratio
- 56In the cross-flow example, the minimum heat-capacity rate belonged to the_____fluid.
Hint
The hot-side heat-capacity rate was about five times smaller than the cold-side rate.
Answer
hot
- 57The cross-flow example had a capacity-rate ratio of approximately_____.
Hint
The hot-side heat-capacity rate was about one-fifth of the cold-side rate.
Answer
0.2
- 58The cross-flow example had an NTU of approximately_____.
Hint
It was calculated from the overall coefficient, heat-transfer area, and minimum heat-capacity rate.
Answer
0.5
- 59The cross-flow example had an effectiveness of approximately_____.
Hint
This value came from the single-pass, both-fluids-unmixed relation.
Answer
0.37
- 60The maximum possible heat transfer in the cross-flow example was approximately_____kilowatts.
Hint
It was calculated using the minimum heat-capacity rate and the largest inlet temperature difference.
Answer
4.8
- 61The hot-fluid outlet temperature in the cross-flow example was_____degrees Celsius.
Hint
The actual heat transfer was used with the hot-side heat-capacity rate and energy balance.
Answer
58.3
- 62Estimating fluid properties at an average temperature and then recalculating after finding the outlet temperature is a way to improve the property estimate through_____.
Hint
This process repeats a calculation using an updated estimate.
Answer
iteration
- 63For liquid water in the examples, the specific heat was described as a relatively weak function of_____.
Hint
The property changes only slightly across the temperature range considered.
Answer
temperature
- 64In saturated-water property tables, the label CP,F identifies the specific heat of the saturated_____.
Hint
The contrasting label for the saturated vapor uses the letter G.
Answer
liquid

Ask anything